Components


CENTRIFUGAL LIQUID CHILLER

COMPONENT

FUNCTION

MAINTENANCE

CONTROL CENTER

  • Provides wiring connection point, safety interlocks, controls, and capacity control for compressor operation.
  • Sequence test all controls.
  • Calibrate and clean controls and safety devices.
  • Inspect and clean electrical contacts.
  • Check and set point of controls and limits.
  • MOTOR

  • Provides energy for compressor operation.
  • Lubricate motor bearings.
  • Check motor insulation resistance.
  • Check condition and alignment of drive section.
  • Measure vibration.
  • Examine motor mount resiliency.
  • MOTOR STARTER

  • Controls on/off operation of motor.
  • Check operating current, voltage and heater size.
  • Inspect starter coils and contacts.
  • TRANSMISSION

  • Provides mechanical link between motor and impeller.
  • Check for proper lubrication
  • COMPRESSOR

  • Prepares refrigerant to be condensed and reused at the evaporator.
  • Check refrigerant charge.
  • Check for refrigerant and oil leaks.
  • Test for proper operation and efficiency.
  • Observe bearing and operating surface temps.
  • Check oil heater operation.
  • Check oil level and condition.
  • Perform acid test.
  • Measure vibration on main bearings.
  • CONDENSER

  • Transfers heat from refrigerant to condenser water.
  • Inspect and clean tubes as required.
  • Inspect for corrosion, clean and paint as required.
  • CONDENSER WATER CONNECTIONS

  • Provides connections for condenser water supply and return.
  • Inspect and check for leaks.
  • Repair or tighten as required.
  • CHILLED WATER CONNECTIONS

  • Provides connections for chilled water supply and return.
  • Inspect and check for leaks.
  • Repair or tighten as required.
  • VANES

  • Regulates the amount of refrigerant vapor entering compressor.
  • Repair as required.
  • Lubricate vane linkages.
  • Check vane control for proper operation.
  • PURGE UNIT

  • Removes non condensables and water vapor from refrigerant system.
  • Lubricate motor.
  • Clean purge drum.
  • Change purge unit oil.
  • Check drive belt and adjust tension.
  • VIBRATION ISOLATORS

  • Reduces noise transmission of unit to building structure.
  • Check for security and resiliency.
  • EVAPORATOR

  • Provides for heat transfer from chilled water to refrigerant.
  • Inspect rupture disc for leaks.
  • Inspect and clean tubes as required.
  • FLOW CONTROL

  • Regulates refrigerant flow from the condenser to the evaporator.
  • Check float control operation as required.
  • LUBRICATION PUMP

  • Supplies oil to critical bearings in compressor.
  • Inspect and check for proper operation.
  • Change oil as required.